ControlPro-Panel update history firmware

Update history

ControlPro/Panel
[Version 3.8.3]

  • USB functionalities now work on the USB port of the ControlPro/HMI instead of the internal USB port inside the ControlPro/Panel:
    • Backup and restore settings
    • Export overall event log
    • Import language files
  • Updated HTML interface for proper operation in Chrome version 80 and higher
  • Improved warnings
    • W106 - Compressed air valve fault; gives more info on measure valve current delta in mA
    • W105 - Compressed air (cleaning active); is now delayed by the "compressed air alert delay" setting in screen (1.5 Alerts).
  • Improved overall event logging
    • Included settings and other system data
    • Improved filtering (interval times and thresholds)
    • Rounding values and added the unit of measure
  • Several small bug fixes


[Version 3.6.1]

  • Added lock mode for homescreen function, see “5.7 Lock mode”.
    • Complete new function to create an extra password protection on the controlling functions of the home screen (start/stop fan, extra timer settings, STOP, manual cleaning).
  • Changed possible events for output relays.
    • None
    • Start/stop fan
    • Cleaning active
    • System mode – Automatic
    • Warning active
    • Alarm active
    • Sliding valve output
    • Warning/alarm (no compressed air)
    • Warning (dustbin)
  • Make several trigger adjustable under “1.5 Alerts”.
    • Added “external fault - trigger”, options: HIGH or LOW.
    • Added “fan alarm - trigger”, options: HIGH, LOW or FAN-MONITORING.
  • Added extra options under “2.3 External start/stop signal”.
    • Pulse on/off (same as start/stop button; pulse changes the status of the fan).
    • Pulse timer on (pulse starts the fan when it was off and triggers an extra timer which can be set from 15 min till 8 hours).
  • Make Ethernet setting configurable under “5.6.1 Configure Ethernet”.
    • Automatic DHCP.
    • Static IP  (IP Address, Subnet mask, Default gateway, Broadcast address, DNS).
  • Extra info in “operational info” screen
  • Added actual value fan frequency (Hz) under “2.2.1 PID setpoint of pressure”.
    • Also in same screen at the end of the wizard
  • Added option to connect OilShield under  “1.1 Fire safety system”.
    • Also added new warning:  W118 OilShield
  • Several small bug fixes

 